Marka | Stahl |
Ürün | LFT HND 24VAC 6147/2 ZONE-1,21 |
Sipariş kodu | IMP4943819 |
Stahl - LFT HND 24VAC 6147/2 ZONE-1,21 ürününün fiyatını ve teslimat süresini öğrenmek için lütfen sorunuzu bize e-postayla gönderin. Diğer model numaraları için de size tavsiyelerde bulunabiliriz. Alman endüstriyel pazarında sizin için en iyi fiyatı ve teslimat süresini bulmaya çalışıyoruz.
Yalnızca yeni ve orijinal ürünler satıyoruz.
(Push button explosion-protected Type : 8602A0001-1 Enclosure material : Polyamide Seal : Standard Mounting : with threaded Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex e II Dust explosion protection : II 2 D Ex tD A21 Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Type of protection (IP) : IP66 Packed : Yes)
(Rotary handle, large, raised explosion-protected Type : 8602A0724-1-ss-0 Enclosure material : Polyamide Seal : Silicone Mounting : with threaded Padlockable in : no position Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex e II Dust explosion protection : II 2 D Ex tD A21 Min. ambient temperature : -50 °C Max. ambient temperature : +70 °C Type of protection (IP) : IP66 Packed : Yes)
(Label I O II)
labels buttons series 8003
Anahtar amplifikatörü dijital giriş
IS PAC Isolating Repeater Switching Repeater Field Circuit Ex i explosion-protected Type : 9170/10-12-21s Max. Voltage Uo : 10,6 V Max. Current Io : 24 mA Max. Demand Po : 64 mW Min. nominal voltage : 120 V Max. nominal voltage : 230 V Nominal current : 12 mA Number of channels : 1 Output / channel : 1 change over contact LFD relay : Yes Line fault transparency : No Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Dust explosion protection : II (1) D [Ex ia] IIIC For further information, see : www.r-stahl.com Web code 9170A Switching Repeater Series 9170, Field Circuit Ex i, single channel Basic function: binary / digital input Intrinsically safe input: [Ex ia] IIC Power supply: 120 ... 230 V AC Input: acc. to EN 60947-5-6 (NAMUR) Output / channel: 1 change-over contact Connection type: Screw terminals
(Notlicht-Langfeldleuchte für Leuchtstofflampen Typ: 6608/5.2-9...-...7 Technische Daten: Gas-Explosionsschutz: II 3 G EEx nAC II T4 Staub-Explosionsschutz: II 2 D T 80°C Prüfschein: DMT 03 E 093/ ATEX E 094 X Geeignet für: Leuchtstofflampe 2Stift, 2 x 18W Reflektorausführung: symmetrisch breitstrahlend Material: Polyesterharz Oberfläche: Ohne Farbgebung Schutzart: IP 66 Umgebungstemperatur: -20°C...40°C Nennspannung: 220 V -10% ... 254 V +10%; 50/60 Hz Kabeleinführung: 2 x Kabeleinführung M25x1,5 1 x Verschlussstopfen M25x1,5 ohne Leuchtmittel Durchverdrahtung mit 6 Leitern Abschaltung beim öffnen der Leuchte (Netzspannung und Batteriekreis) mit Betriebsdauertest)
Reparatursatz 2x36W QTP8 Ers.QTIS-B Elektronisches Vorschaltgerät + Zubehör
Reparatursatz 2x18W QTP8 Ers. QTISElektronisches Vorschaltgerät + Zubehör
Control Pendant selection STH 6102-009
Switch socket 3P+N+PE 63A, 200/346-240/415V, 50+60Hz, red CCT No.: 85366990 DE Net weigth: 7,800 KG
Switch socket 3P+N+PE 63A, 200/346-240/415V, 50+60Hz, red CCT No.: 85366990 DE Net weigth: 7,800 KG
Anahtar priz patlamaya karşı korumalı
(Safety Switches 16 A explosion-protected Rated operational voltage AC : 400 V Rated operational current : 16 A Enclosure material : Polyester resin glass fibre-reinforced Detailed number of poles : 3 P Auxiliary contact NC : without Auxiliary contact NO : 1 NO lagging Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex de IIC T6 Gb Dust explosion protection : II 2 D Ex tb IIIC 80 °C Db Min. ambient temperature : -40 °C Max. ambient temperature : +51 °C Special conditions for extended ambient temperature, see operating instructions: Extended min. ambient temp. : -40 °C Extended max. ambient temp. : +69 °C Type of protection (IP) : IP66 Colour of handle : standard black Cable gland : 2 x M25 Ø 7 ... 17 mm 1 x M20 Ø 6 ... 13 mm Connection cross-section : 2,5 ... 6 mm2 Connection cross-section aux.: 1,5 ... 4 mm2 finely-stranded 1,5 ... 6 mm2 solid CCT No.: 85365080 DE Net weigth: 1,590 KG)
(Safety Switches 16 A explosion-protected Rated operational voltage AC : 400 V Rated operational current : 16 A Enclosure material : Polyester resin glass fibre-reinforced Detailed number of poles : 3 P Auxiliary contact NC : without Auxiliary contact NO : 1 NO lagging Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex de IIC T6 Gb Dust explosion protection : II 2 D Ex tb IIIC 80 °C Db Min. ambient temperature : -40 °C Max. ambient temperature : +51 °C Special conditions for extended ambient temperature, see operating instructions: Extended min. ambient temp. : -40 °C Extended max. ambient temp. : +69 °C Type of protection (IP) : IP66 Colour of handle : standard black Cable gland : 2 x M25 Ø 7 ... 17 mm 1 x M20 Ø 6 ... 13 mm Connection cross-section : 2,5 ... 6 mm2 Connection cross-section aux.: 1,5 ... 4 mm2 finely-stranded 1,5 ... 6 mm2 solid CCT No.: 85365080 DE Net weigth: 1,590 KG)
6141/61-16 Hand lamp with LED Hand Lamp Series 6141/6, explosion protected Rated data: 3 V Batteries: Hand lamps are supplied with batteries. For other battery types see operating instructions For use in: Zones 1 & 2, 21 & 22
Fiber optik üst parça
Kemer çantası
YO3/ISC/T4 ATX YO3 Hupe Ex i ATEX, T4
YO5/ISC/T6 ATX YO5 Hupe Ex i ATEX, T6
MCP/PB/SP/Ex/A+B+C+D/EU/R/LED/D/T Drucktaster-Handfeuermelder, 12-50VDC/
Batterie 6148 6V 4,5Ah replacement set
Diffusing lens clear accessories
Befehls- und Meldegeraet
Lighting with 1-pin 1x18/20W
18W EXPROOF
Light fitting for fluorescent lamps explosion -protected