Marka | Vaisala |
Ürün | HMP360 8M1A3N2 |
Sipariş kodu | IMP4320702 |
Vaisala - HMP360 8M1A3N2 ürününün fiyatını ve teslimat süresini öğrenmek için lütfen sorunuzu bize e-postayla gönderin. Diğer model numaraları için de size tavsiyelerde bulunabiliriz. Alman endüstriyel pazarında sizin için en iyi fiyatı ve teslimat süresini bulmaya çalışıyoruz.
Yalnızca yeni ve orijinal ürünler satıyoruz.
dijital barometre
Digital Barometer Model : PTB330 Series
(Pressure, Humidity andTemperature Transmitter PTU301 Baro-1 Module ClassA 500-1100 hPa,2pcs BARO-1 0.25m Probe Cable Graphic display with keypad Galvanic Isolation Module Analog Output (CH1,CH2) Output 4...20mA Channel 1 RH (0...100%RH) Channel 2 T (Range See Below) Temperature Range -20...+60C PTU200 Output Format Standard Metric Units Sealed Cable Gland M20x1.5 Pressure Connector M5 (10-32) Wall Mounting Kit with Probe Holder Humicap180R Sensor Stainless Steel Filter HM47453 User´s Guide PTU300 Software Interface Kit with USB-RJ45 Cable)
(Druck-, Feuchte- und Temperaturmesswertgeber PTU30T Klasse A / 1 Drucksensor Druckbereich: 500…1100 hP 2 m Kabel, PTU30T grafisches LCD mit Hintergrundbeleuchtung Spannungsversorgung Standard (24 VDC) Analogausgang Output 4...20mA Kanal 1 T (Bereich siehe unten) Kanal 2 T (Bereich siehe unten) Kanal 3 P (gesamter Druckbereich) Analog Output Module T-compensated Temp.-Bereich -40...+60C Signalformat Standard metrische Einheiten Kabelverschraubung M20 x 1,5 Schlauchtülle für 1/8 " Schlauch Bedienungsanleitung PTU300)
(Druck-, Feuchte- und Temperaturmesswertgeber PTU30T Klasse A / 1 Drucksensor Druckbereich: 500…1100 hP 2 m Kabel, PTU30T Temp.-Sonde an 2 m Kabel Gehäuse ohne Display Spannungsversorgung Standard (24 VDC) Analogausgang Output 4...20mA Kanal 1 T (Bereich siehe unten) Kanal 2 T (Bereich siehe unten) Kanal 3 P (gesamter Druckbereich) Analog Output Module T-compensated Temp.-Bereich -40...+60C Signalformat Standard metrische Einheiten Kabelverschraubung M20 x 1,5 Schlauchtülle für 1/8 " Schlauch Bedienungsanleitung PTU300)
Basınç, Nem ve Sıcaklık Transmitteri
(Druck-, Feuchte- undTemperaturmesswertgebe)
Druck-, Feuchte- und Temperaturmesswertgeber PTU301 1 EA Wandmontageplatte Kunststoff 1 EA Feuchtesensor HUMICAPR mit Filterelektrode 1 EA PPS Gitter mit Edelstahlnetz 1 EA Bedienungsanleitung PTU300 1 EA Klasse B / 1 Drucksensor Druckbereich: 500…1100 hP 1 EA HMP301P90 Baugruppe 1 EA grafisches LCD mit Hintergrundbeleuchtung 1 EA 100...240 VAC Netzmodul 1 EA Analogausgang Output 4...20mA 1 EA Kanal 1 rF (0...100 %rF) 1 EA Kanal 2 T (Bereich siehe unten) 1 EA Kanal 3 P (gesamter Druckbereich) 1 EA Analog Output Module T-compensated 1 EA Temp.-Bereich -20...+60°C 1 EA Signalformat Standard 1 EA metrische Einheiten 1 EA Kabelverschraubung M20 x 1,5 2 EA Schlauchtülle für 1/8 " Schlauch 1 EA
(Pressure, Humidity andTemperature Transmitter PTU301 Baro-1 Module ClassA 500-1100 hPa,2pcs BARO-1 0.25m Probe Cable Sealed Cable Gland M12x1,5 Graphic display with keypad Standard (24 VDC) Analog Output (CH1,CH2) Output 4...20mA Channel 1 RH (0...100%RH) Channel 2 T (Range See Below) Temperature Range -20...+60C PTU200 Output Format Standard Metric Units Sealed Cable Gland M20x1.5 Pressure Connector M5 (10-32) Wall Mounting Kit with Probe Holder Humicap180R Sensor Stainless Steel Filter HM47453 User´s Guide PTU300 Software Interface Kit with USB-RJ45 Cable)
(Druck-, Feuchte- und Temperaturmesswertgeber PTU30T Klasse A / 1 Drucksensor Druckbereich: 500…1100 hP 2 m Kabel, PTU30T Gehäuse ohne Display Spannungsversorgung Standard (24 VDC) Analogausgang Output 4...20mA Kanal 1 T (Bereich siehe unten) Kanal 2 T (Bereich siehe unten) Kanal 3 P (gesamter Druckbereich) Analog Output Module T-compensated Temp.-Bereich -40...+60C Signalformat Standard metrische Einheiten Kabelverschraubung M20 x 1,5 Schlauchtülle für 1/8 " Schlauch Bedienungsanleitung PTU300)
(Druck-, Feuchte- und Temperaturmesswertgeber PTU30T Klasse A / 1 Drucksensor Druckbereich: 500…1100 hP 2 m Kabel, PTU30T Temp.-Sonde an 2 m Kabel grafisches LCD mit Hintergrundbeleuchtung Spannungsversorgung Standard (24 VDC) Analogausgang Output 4...20mA Kanal 1 T (Bereich siehe unten) Kanal 2 T (Bereich siehe unten) Kanal 3 P (gesamter Druckbereich) Analog Output Module T-compensated Temp.-Bereich -40...+60C Signalformat Standard metrische Einheiten Kabelverschraubung M20 x 1,5 Schlauchtülle für 1/8 " Schlauch Bedienungsanleitung PTU300)
Görüş sensörü
Radiosonde
Static Pressure Heads for Manimizing Wind Induced
Kabelbox mit Über-spannungsschutz
Global solar radiation sensor, Model: QMS101
Anemometer windspeed sensor, Model: CMP3
Wind speed direction sensor, Model: WM30
Atmospheric pressure sensor, Model: PMT16A-M3
Temperature and humidity sensor, Model: QMH102
Rain precipitation sensor, Model: QMR102